GETTING STARTED
Your first positioning session.
Start with a library setup, then make one adjustment at a time.
Start with a setup
- Open the lab and wait for the skeleton. The first load includes 3D models and material textures. A desktop or laptop is currently the best starting point.
- Choose Open library. Search for a body part or position, read the reference notes, then select Choose this position. The dialog closes and the camera frames the patient. A compatible current receptor is kept; otherwise the recipe selects its default.
- Select a part. Click the skeleton picker, click a bone in the room, or use the Part menu. Left, Right, and Bilateral control which side you adjust.
- Make an adjustment. Drag a dial, scroll over it, or type a numeric value. Patient and tube changes update the live bone projection.
- Review and capture. Move or resize the X-ray viewer. Capture downloads a PNG to your device. It does not save the pose.
Keep these controls close
| Action | Control |
|---|---|
| Look around | Drag in empty room space to orbit; scroll to zoom. Fit patient brings the skeleton back into view. |
| Fine adjustment | Hold Shift while adjusting a dial. Arrow keys adjust a focused dial; its numeric field accepts a typed value. |
| Move the whole patient | Use Move body or Rotate body in the picker. Translation uses inches; rotation uses degrees. |
| Adjust the pelvis | Select Sacrum & Pelvis for pelvic tilt, left/right hip hike, and sit up/down at the hips. |
| Adjust the beam | Choose Move, Rotate, or Collimate under X-ray tube. Use Center to target the selected part. |
| Label the setup | Double-click Current Position or press F2. Enter confirms; Escape cancels. Geometry changes clear the label. Labels are session-only. |
| Recover the view | Fit patient changes the camera. Reset patient changes the patient pose. These are different actions. |
Changing the receptor loads its default setup. Loading another library position replaces the current setup. There is currently no undo history or saved-pose library.
Make the workspace comfortable
Settings has Display adjustments, Sensitivity, Colors, and Lighting. Changes preview immediately. Click Save to retain the open submenu’s settings; Save from the main settings menu retains all settings.
Equipment and skeleton colors can be adjusted while retaining the selected material’s texture detail. Revert to default affects the open category; save afterward if you want to keep the defaults.
Settings are stored in this browser. Clearing this site’s browser data removes them. They do not follow you to another browser or device. Opening this guide in another tab leaves your lab session open.
CURRENT DEMO SCOPE
Use the preview with context.
- Educational exploration. This is not a diagnostic image system, treatment tool, patient-care planning tool, or substitute for qualified instruction.
- Bone-only imaging. Soft tissue, organs, scatter, exposure calibration, and validated clinical image quality are not included.
- Provisional articulation. Joint motion and equipment contact are geometric approximations. Collision limits use conservative bounds; they are not soft-tissue or self-collision physics. Presets load instantaneously.
- Library starters. Loading a named method does not establish exact clinical reproduction. Review the entry’s notes and verification caveats and fine-position against an authorized, reliable reference.
- Review pending. Qualified educator signoff, learning-outcome evaluation, and a complete browser/device acceptance matrix are not complete.
- Phone support is still in development. The lab may be slow or difficult to use on small screens. This guide and the product pages are designed for smaller screens.
Do not enter patient identifiers or use real patient information in position names or support reports.